st jude heart valve anticoagulation | 合法醫療器材資訊網
由PDStein著作·2001·被引用395次—JudeMedicalvalvesintheaorticposition.3.LevelsoforalanticoagulantsthatprolongtheINRto2.0to3.0appearsatisfactoryforpatientswithSt.Jude ...,由BYamak著作·1999·被引用23次—FollowingimplantationoftheSt.JudeMedicalmechanicalheartvalveprosthesis,afixeddoseof2.5mg/daywarfarinandcombineddipyridamole/aspirin ...,由SFKatircioglu著作·1998·被引用24次—Low-doseoralanticoagulationaftermitralvalvereplacementwithSt.JudeMedicalprosthesisinelderlypatientsprovidedsatisfactoryclinical...
st jude's valve st. jude aortic valve anticoagulation guidelines mechanical heart valve anticoagulation guidelines why are noacs contraindicated in mechanical valves mechanical aortic valve bridging guidelines bioprosthetic mitral valve pulmonary valve replacement anticoagulation heparin for mechanical valve Bioprosthetic valve Mechanical valve NOAC Valvular heart disease guideline bioprosthetic valve中文 Mechanical valve INR Tissue valve warfarin Mechanical valve heparin bridge Valve replacement anticoagulation guidelines Epic valve St Jude mechanical valve Mechanical valve Artificial valve Porcine valve SJM mitral valve Regent mechanical heart valve “凱樂思馬丁”電刀握把及附件 輝你智有限公司 衛 部 醫器 製 壹 字 第 008527 號 藥 販 字號 查詢 骨折拆鋼釘復原時間 starbond easy powder 30 co cr disc s&t microvascular clamps
Antithrombotic therapy in patients with mechanical and ... | 合法醫療器材資訊網
由 PD Stein 著作 · 2001 · 被引用 395 次 — Jude Medical valves in the aortic position. 3. Levels of oral anticoagulants that prolong the INR to 2.0 to 3.0 appear satisfactory for patients with St. Jude ... Read More
Low | 合法醫療器材資訊網
由 B Yamak 著作 · 1999 · 被引用 23 次 — Following implantation of the St. Jude Medical mechanical heart valve prosthesis, a fixed dose of 2.5 mg/day warfarin and combined dipyridamole/aspirin ... Read More
Mitral valve replacement with St. Jude Medical prosthesis and ... | 合法醫療器材資訊網
由 SF Katircioglu 著作 · 1998 · 被引用 24 次 — Low-dose oral anticoagulation after mitral valve replacement with St. Jude Medical prosthesis in elderly patients provided satisfactory clinical results. Read More
Aortic valve replacement with the St. Jude Medical prosthesis ... | 合法醫療器材資訊網
由 SF Katircioglu 著作 · 1997 · 被引用 13 次 — Jude Medical valve may allow the use of a low level of anticoagulation. This study shows that fixed dose oral anticoagulation does not increase the rate of ... Read More
Acute mechanical valve thrombosis of the St. Jude medical ... | 合法醫療器材資訊網
由 SF Katircioğlu 著作 · 1999 · 被引用 15 次 — Sixty experienced mechanical valve thrombosis. Seventeen of 60 patients (28.3%) had isolated aortic valve replacements, 33 had isolated mitral valve ... Read More
Anticoagulation in patients with mechanical heart valves ... | 合法醫療器材資訊網
由 FWA Verheugt 著作 · 2015 · 被引用 9 次 — The St. Jude Medical prosthesis in the aortic position, which was used in half of the patients, is considered a valve with a low thrombotic ... Read More
Intensity of oral anticoagulation after implantation of St. Jude ... | 合法醫療器材資訊網
由 D Pruefer 著作 · 2001 · 被引用 59 次 — Thrombotic and thromboembolic complications are important causes of late morbidity and mortality in patients after prosthetic heart valve replacement. Read More
Mechanical aortic valve without anticoagulation for 33 years in ... | 合法醫療器材資訊網
由 K Aman 著作 · 2016 · 被引用 2 次 — A 46-year-old Yemeni man had an aortic valve replacement, using a St Jude Medical mechanical valve, 33 years ago due to aortic regurgitation ... Read More
Antithrombotic therapy for surgical prosthetic heart valves and ... | 合法醫療器材資訊網
由 WH Gaasch 著作 · 被引用 2 次 — For patients with an On-X mechanical bileaflet aortic valve with no other risk factors for thromboembolism, we suggest anticoagulation with a ... Read More
相關資訊整理
【“翁克斯”人工心瓣膜】許可證字號:衛署醫器輸字第019794號
器材品名:“翁克斯”人工心瓣膜許可證字號:衛署醫器輸字第019794號註銷狀態:註銷日期:註銷理由:有效日期:2024/04/22發證日期:2...
【“聖猷達”人工機械瓣膜】許可證字號:衛署醫器輸字第009282號
器材品名:“聖猷達”人工機械瓣膜許可證字號:衛署醫器輸字第009282號註銷狀態:註銷日期:註銷理由:有效日期:2024/02/09發證日期...
【“盎格思”人工心臟瓣膜】許可證字號:衛部醫器輸字第034051號
器材品名:“盎格思”人工心臟瓣膜許可證字號:衛部醫器輸字第034051號註銷狀態:註銷日期:註銷理由:有效日期:2025/10/13發證日期...