nova | 合法醫療器材資訊網
由MCox著作·2002·被引用26次—TheNovaT®(andformerlytheidenticalNovagard®)IUDshavecopperwithasurfaceareaof200mm2.TheNovaT380®hascopperwithasurfaceareaof380 ...,Thedeviceusedinthisstudy,theNova-T380,hascopperwithasurfacearea...1,2Ithasbeensuggestedthatthecontraceptiveefficacyofcopperintrauterine ...,由WVNorman著作·2012·被引用2次—...ofeitheraFlexi-T380(+)IUD,adeviceforwhichnocurrentevidenceonexpulsionoreffectivenessratesisavailable,ortheNova-T200IUD, ...,由GFarr著作·1994·被引用29次—16.WorldHealth...
nova t 380 iud nova t 380 coil nova t 200 vs 380 nova t 380 price egypt nova t 380 weight gain nova t 380 vs mirena nova t 380 after 5 years nova t 380 size nova t 380 weight loss nova t 380 vs mirena nova t 380 hormones nova t 380 insertion technique nova t 380 side effects nova t 380 price nova t 380 after 5 years nova t 380 reviews diapex plus alice nightone accuracy GE MRI 點滴種類介紹 port a給藥 中央靜脈導管 永信光學ptt 永 信 光學 台中
Clinical performance of the Nova T380® intrauterine device in ... | 合法醫療器材資訊網
由 M Cox 著作 · 2002 · 被引用 26 次 — The Nova T® (and formerly the identical Novagard®) IUDs have copper with a surface area of 200 mm2. The Nova T380® has copper with a surface area of 380 ... Read More
Clinical performance of the Nova | 合法醫療器材資訊網
The device used in this study, the Nova-T380, has copper with a surface area ... 1, 2 It has been suggested that the contraceptive efficacy of copper intrauterine ... Read More
Comparing the effectiveness of copper intrauterine devices ... | 合法醫療器材資訊網
由 WV Norman 著作 · 2012 · 被引用 2 次 — ... of either a Flexi-T380(+) IUD, a device for which no current evidence on expulsion or effectiveness rates is available, or the Nova-T200 IUD, ... Read More
Contraceptive efficacy of the Copper T 380A and Copper T ... | 合法醫療器材資訊網
由 G Farr 著作 · 1994 · 被引用 29 次 — 16. World Health Organization. The TCu 380A, TCu 220C, Multiload 250 and Nova T IUDs at 3, 5, and 7 years of use: ... Read More
Five | 合法醫療器材資訊網
由 I Batár 著作 · 2002 · 被引用 32 次 — In an open, single-group, phase III clinical trial of 5 years, the clinical performance of NOVA T 380 was investigated in three centers. The device having a higher ... Read More
Five | 合法醫療器材資訊網
One perforation was recorded; the calculated rate is 0.3 per 100 women (first year). The continuation rate was 88.3 and 52.5 at 1 and 5 years, respectively. In ... Read More
Five | 合法醫療器材資訊網
由 I Batár 著作 · 2002 · 被引用 32 次 — Amatya R. Contraceptive efficacy of the Copper T 380A and Copper T intrauterine devices. Contraception. 1994; 200;49: ... Read More
NOVA T 380 | 合法醫療器材資訊網
NOVA T 380 is inserted into the uterine cavity. It is effective for five years. Insertion and removal/replacement: Before insertion, the woman must be informed on the ... Read More
Two-year clinical experience with Nova | 合法醫療器材資訊網
由 I Batár 著作 · 1999 · 被引用 13 次 — Contraceptive efficacy of the Copper T 380A and Copper T 200 intrauterine devices: results from comparative clinical trials in six developing countries. Read More
相關資訊整理
【母體樂銅-375〝母體適〞】許可證字號:衛署醫器輸字第007860號
器材品名:母體樂銅-375〝母體適〞許可證字號:衛署醫器輸字第007860號註銷狀態:已註銷註銷日期:2012/11/15註銷理由:許可...
【樂母麗避孕器】許可證字號:衛署醫器輸字第006908號
器材品名:樂母麗避孕器許可證字號:衛署醫器輸字第006908號註銷狀態:註銷日期:註銷理由:有效日期:2023/05/10發證日期:1993/05...
【母體樂銅-375】許可證字號:衛署醫器輸字第007233號
器材品名:母體樂銅-375許可證字號:衛署醫器輸字第007233號註銷狀態:已註銷註銷日期:1996/09/02註銷理由:中文品名變更;;...