miragel scleral buckle | 合法醫療器材資訊網
由ERReshef著作·2020·被引用1次—TheMIRAgel(hydrogel)scleralbuckle,introducedinthe1980s,wasanovelmaterialtorepairretinaldetachments.Itwaslaterdiscontinuedduetothe ...,由MRoh著作·2018·被引用6次—MIRAgel(MIRA,Waltham,MA)isahydrogelbucklethatwasintroducedin1979asanewscleralimplantforthetreatmentofretinaldetachment.Long-term ...,由CLShields著作·2005·被引用24次—MIRAgelscleralbucklematerialcangreatlyenlargeoveraperiodof10yearsandsimulateanorbitaltumorororbitalcyst.Patientsoftendonotrecalldetailsof .....
mira inc mira inc scleral buckle mirainc net NeuRx Diaphragm Pacing System 致達生醫股份有限公司 B braun hernia mesh 自費比價網 安斯泰來藥品 安斯泰來活路利淨 台灣中外製藥股份有限公司 ptt "B
Clinical and radiographic features of hydrolyzed MIRAgel ... | 合法醫療器材資訊網
由 ER Reshef 著作 · 2020 · 被引用 1 次 — The MIRAgel (hydrogel) scleral buckle, introduced in the 1980s, was a novel material to repair retinal detachments. It was later discontinued due to the ... Read More
Complications Assoicated with MIRAgel for Treatment of ... | 合法醫療器材資訊網
由 M Roh 著作 · 2018 · 被引用 6 次 — MIRAgel (MIRA, Waltham, MA) is a hydrogel buckle that was introduced in 1979 as a new scleral implant for the treatment of retinal detachment. Long-term ... Read More
Expanding MIRAgel scleral buckle simulating an ... | 合法醫療器材資訊網
由 CL Shields 著作 · 2005 · 被引用 24 次 — MIRAgel scleral buckle material can greatly enlarge over a period of 10 years and simulate an orbital tumor or orbital cyst. Patients often do not recall details of ... Read More
Globe Loss From Intraocular Invasion of MIRAgel Scleral ... | 合法醫療器材資訊網
由 TJ Rubinstein 著作 · 2016 · 被引用 8 次 — Globe Loss From Intraocular Invasion of MIRAgel Scleral Buckle Components. Ophthalmic Plast Reconstr Surg. Sep-Oct 2016;32(5):329-32. doi: ... Read More
Good Ideas Gone Bad | 合法醫療器材資訊網
由 JT Thompson 著作 · 2016 · 被引用 5 次 — The enlargement of the MIRAgel scleral buckle increased progressively, so patients did not experience problems until 5 to 10 years after their retinal detachment. Read More
MIRAgel Buckle Extrusion With Preseptal Cellulitis and ... | 合法醫療器材資訊網
由 MW Orban 著作 · 2016 · 被引用 1 次 — MIRAgel (MIRA, Waltham, MA) scleral buckle material was initially developed in the 1980s as an alternative to more traditional silicone buckles. Read More
Removal of Hydrogel Scleral Buckles | 合法醫療器材資訊網
This episcleral hydrogel (methylacrylate-2-hydroxyethylacrylate) buckle (Miragel, Mira) was promoted especially because of its soft and pliable characteristics ... Read More
Removal of MIRAgel Scleral Buckle Implants | 合法醫療器材資訊網
由 P Santorum 著作 · 2020 · 被引用 1 次 — Removal of MIRAgel Scleral Buckle Implants. The Direct Aspiration Technique. Santorum, Paolo MD *; De Vitto, Antonia Maria Luce MD *,† ... Read More
相關資訊整理
【"佛朗惜眼" 鞏膜環扣物】許可證字號:衛署醫器輸字第010377號
器材品名:"佛朗惜眼"鞏膜環扣物許可證字號:衛署醫器輸字第010377號註銷狀態:註銷日期:註銷理由:有效日期:2023/08/20發證日期...
【視網膜剝離手術用之內植物】許可證字號:衛署醫器輸字第005367號
器材品名:視網膜剝離手術用之內植物許可證字號:衛署醫器輸字第005367號註銷狀態:已註銷註銷日期:2007/07/20註銷理由:許可證...
【視網膜剝離手術用之內植物】許可證字號:衛署醫器輸字第001228號
器材品名:視網膜剝離手術用之內植物許可證字號:衛署醫器輸字第001228號註銷狀態:已註銷註銷日期:1988/09/14註銷理由:有效期...