5th EFLM Conference on Preanalytical Phase Zagreb (HR ... | 合法醫療器材資訊網
Gunn B.B. Kristensen (NO)
Preanalytical cases A PARADIGMATIC CASE OF SPURIOUS HYPERKALEMIA IN BLOOD GAS ANALYSISG.L. Salvagno1, D. Demonte 1, G. Lippi 1
1Section of Clinical Biochemistry, University Hospital of Verona, Verona, Italy
BACKGROUND-AIM: We describe a paradigmatic case of spurious hyperkalemia in blood gas analysis due to inappropriate transport conditions of a heparinized syringe.
METHODS: A 51-year old male patient was admitted to the local hospital with dyspnea. Venous blood was drawn by a nurse into a 3.0 mL heparinized syringe (Smiths Medical), and sent to the central laboratory, for analysis of blood gases.
RESULTS: Blood gas analysis, performed with GEM Premier 4000 (Instrumentation Laboratory), revealed a substantially normal blood gas profile except ...